10 Ton Glycol Chiller

SA10DSN-3-2P100T – Packaged Air Cooled Chiller
Self-contained industrial packaged air-cooled chiller that are easy to install, low water usage and no mechanical room requirements. This unit can be installed indoors or outdoors and has a minimal footprint.

STANDARD FEATURES:

  • High Efficient R-410A Refrigerant
  • Copeland Scroll compressor(s)
  • Insulated Stainless steel copper-brazed plate evaporator(s) (others available)
  • Cast iron end suction centrifugal supply pump rated at 2.4 gpm per ton at 100 feet TDH (Stainless available)
  • Insulated polypropylene reservoir with fill port and liquid level sight glass (larger volumes available)
  • Thermostatic expansion valve, filter drier, sight glass installed on refrigerant circuit(s)
  • Service ports and valves
  • NEMA 4 control panel with digital temperature controller
  • High and low pressure safety
  • Single point power connection
  • Direct drive fan(s) made to run slower and more quiet
  • Vertical air discharge fans minimizes operating sound
  • Weather resistant fan motor made to survive in the elements.
  • Highly efficient coil provides excellent heat transfer and low air resistance
  • Energy Star qualified unit
  • Assembled, plumbed, and wired on industrial epoxy-coated steel frame
  • Refrigerant circuit(s) pressure tested for leaks with nitrogen charge
  • Refrigerant circuit(s) vacuum tested for leaks to negative-psi pressure
  • Refrigerant circuit(s) fully charged with refrigerant
  • Hydronic circulation loop leak tested under full flow using the WHALE-SOFT™ Testing Platform
  • Complete systems fully run tested under heat load using the WHALE-SOFT™ Testing Platform
Description

TECHNICAL DATA:

  • Cooling Performance at 50F Glycol / 95F Ambient / 0% Glycol
  • Nominal Tons: 10 Tons
  • KW: 35.10 kw (47 hp)
  • BTU/hr: 120,000
  • Cooling Performance at 25F Glycol / 95F Ambient / 50% Glycol
  • Nominal Tons: 5.66 Tons
  • KW: 19.87 kw (26.6 hp)
  • BTU/hr: 67,920

Refrigeration Circuit Details:

  • Compressor Qty: 1
  • Configuration: Single Circuit, Dual Stage
  • Compressor Qty: 1
  • Evaporator Qty: 1
  • Condenser Qty: 1

Pump and Tank Details:

  • Supply Pump Flow & Pressure: 12 gpm to 14.4 @ 100′ tdh (43psi)
    Tank Volume: 100 gallon

Connections:

  • Inlet/Outlet: 1.25 inch FNPT

Physical Data:

  • Length: 48 inches
  • Width: 48 inches
  • Height: 75.2 inches

Electrical Specifications:

  • Voltage: 208-240v / 3-phase / 60hz
  • UNIT FLA: 47.7
  • UNIT MCA: 59.625
  • UNIT MOCP: 60.0